EN ISO 10582
General properties
Dimensions
Test result: 180 × 1220 mm, 300 × 600 mm
Test method: ISO 24342
Requirements: EN ISO 10582
Total thickness with integrated underlayment
Test result: 6.0 mm
Test method: ISO 24346
Requirements: EN ISO 10582
Wear layer thickness
Test result: 0.5 mm
Test method: ISO 24340
Requirements: EN ISO 10582
Mass per unit area
Test result: 10 × 103 g/m2
Test method: ISO 23997
Requirements: EN ISO 10582
Residual indentation
Test result: 0.02 mm
Test method: ISO 24343-1
Requirements: EN ISO 10582
Dimensional stability and curling after exposure to heat
Test result: 0.05 %
Test method: ISO 23999
Requirements: EN ISO 10582
Castor chair test
Test result: no damage, no delamination
Test method: ISO 4918:2016 (EN 425)
Requirements: EN ISO 10582
Colour fastness
Test result: ≥ 6
Test method: ISO 105 B02
Requirements: EN ISO 10582
Class of use

Class of use - Domestic
Test result: class 23 / AC 3
Test method: ISO 10874 (EN 685)
Requirements: EN ISO 10582

Class of use - Commercial
Test result: class 33 / AC 5
Test method: ISO 10874 (EN 685)
Requirements: EN ISO 10582

Class of use - Industrial
Test result: class 42 / AC 6
Test method: ISO 10874 (EN 685)
Requirements: EN ISO 10582
Health and thermal resistance
Formaldehyde emissions
Test result: not detected
Test method: ASTM D6007-2014 (UV-Vis)
Pentachlorophenol (PCP) content
Test result: not detected
Test method: ASTM F 963-11 (ICP-OES)
Thermal resistance
Test result: 0.025 m2·K·W-1
Downloads
Documents SPC.
SPC catalogue 2024 - decors
PDF · 13.2 MB
Download →
Care and cleaning guide - SPC Optimal
PDF · 115 KB
Download →
Installation method SPC interior
Step-by-step flooring installation and removal.
View →
Interior SPC
SPC samples at the dealer.
You can view Woodlook® Optimal SPC decors in person at our partners throughout Slovakia. They will also prepare a price quotation for you.